Liquid-Liquid Extraction Calculator
Design countercurrent extraction systems using distribution coefficients
Input Parameters
Higher K = better extraction
Quick Reference
- • K > 1: Solute prefers extract phase
- • K < 1: Solute prefers raffinate phase
- • Higher S/F: More stages, less solvent per stage
- • Extraction factor (A) = K × (S/F)
Design Results
Theoretical Stages
2
(1.00 exact)
Recovery
75.0%
15.00 kg/h
Stream Properties
Extract Flow:150.0 kg/h
Raffinate Flow:100.0 kg/h
Extract Composition:10.00%
Extraction Factor (A):3.00
Single Stage Comparison
Single stage would give:x = 5.00%
vs target 5.00%
Design Recommendations
- ✓ Good extraction factor - efficient separation
- ⚠ Low recovery - increase stages or S/F ratio
Learn More
Understand the principles of liquid-liquid extraction, distribution coefficients, and stage calculations.