Flowsheet Simulator

How accurate is the flowsheet simulator?

40 checks against independent references, run live against the build you are using. Each row is a small flowsheet (a feed, one unit, products) whose answer is known from a reference equation of state, a thermochemical table or a hand calculation. Deviations are shown as they are, including the ones a cubic equation of state is known for.

What the references are

  • Reference equations of state: IAPWS-95 for water and the Helmholtz-energy formulations for propane, n-butane, benzene, ethanol, nitrogen and CO₂ (the ones behind NIST REFPROP), evaluated with CoolProp. These are fits to measured data and the accepted standard for pure fluids.
  • NIST Chemistry WebBook: ideal-gas enthalpies of formation for the heat of reaction.
  • Raoult’s law with Antoine constants for benzene-toluene, a near-ideal pair where the measured bubble point (92.1 °C) agrees with it.
  • Perry’s Chemical Engineers’ Handbook: the ethanol-water azeotrope at 1 atm.
  • Colebrook equation iterated by hand with IAPWS water properties for the pipe friction factor and pressure drop; Q·ΔP and ΔP/(ρg) for the pump.
  • Aspen Plus V14 RadFrac for the rigorous column: the depropanizer (21 stages, feed on 10, reflux ratio 2.223, 40 kmol/h distillate, 15 bar, PENG-ROB) built and run in Aspen Plus with the same specifications; product compositions, duties and the stage temperatures are compared; the same column with a partial condenser and Murphree efficiency 0.7, a lean-oil absorber with neither condenser nor reboiler, and the depropanizer with a liquid side draw and then a cooled pumparound, were run the same way.

What to expect from a cubic equation of state

The simulator runs on Peng-Robinson or SRK (NRTL and UNIFAC for polar liquids), the same models commercial simulators default to. They reproduce hydrocarbon saturation points within a few tenths of a kelvin and latent heats within a few percent, and they are weakest for water and hydrogen-bonded fluids (about 1 K on the boiling point) and near a critical point (a few kelvin on a Joule-Thomson end state). Liquid densities are taken from fitted correlations rather than the cubic, which would put water 15 % low. Where a steam or refrigerant point matters, the Property Calculator uses the reference equations directly.

0 of 40 done…

Pure fluids

CaseReferenceSimulatorDeviationSource
Water boiling point at 1 atm
Flash water to a vapour fraction of 0.5 at 101.325 kPa; the drum temperature is the saturation point. Peng-Robinson is about 1.4 K high for water; use the Property Calculator (IAPWS) when a steam point matters.
99.97 °CIAPWS-95 (CoolProp)
Water latent heat at 1 atm
Enthalpy of the vapour outlet minus the liquid outlet of the same flash.
40.65 kJ/molIAPWS-95 (CoolProp)
Propane boiling point at 1 atm
Same flash on propane.
-42.11 °CLemmon et al. EOS (CoolProp)
Propane latent heat at 1 atm
Vapour minus liquid outlet enthalpy.
18.77 kJ/molLemmon et al. EOS (CoolProp)
n-Butane boiling point at 1 atm
Same flash on n-butane.
-0.49 °CBuecker & Wagner EOS (CoolProp)
Benzene boiling point at 1 atm
Same flash on benzene.
80.07 °CThol et al. EOS (CoolProp)
Ethanol boiling point at 1 atm
Same flash on ethanol, a polar fluid where a cubic EOS is at its weakest. Cubic equations miss hydrogen bonding; expect about 1 K.
78.42 °CSchroeder et al. EOS (CoolProp)
Isentropic compression of nitrogen, 1 → 4 bar from 30 °C
Compressor at 100 % isentropic efficiency; the outlet temperature is the PS-flash state.
176.80 °CSpan et al. EOS (CoolProp); ideal gas with k = 1.4 gives 177.3
Isentropic power for 36 kmol/h of nitrogen, 1 → 4 bar
Shaft power of the same compressor (10 mol/s).
42.88 kWSpan et al. EOS (CoolProp)
Joule-Thomson expansion of nitrogen, 50 → 1 bar from 25 °C
Valve (isenthalpic); the outlet temperature shows the real-gas departure. The whole effect is 10 K of departure from ideal-gas behaviour; a cubic EOS gets most of it.
15.02 °CSpan et al. EOS (CoolProp)
Joule-Thomson expansion of CO₂, 50 → 10 bar from 40 °C
Valve on a gas close to its critical point. Near the critical point the cubic EOS is a few kelvin off; the sign and size of the cooling are right.
-7.41 °CSpan & Wagner EOS (CoolProp)
Liquid water density at 25 °C, 5 bar
Feed stream density as the inspector shows it. Liquid volumes come from fitted correlations, not the cubic EOS (which would give 849).
997.2 kg/m³IAPWS-95 (CoolProp)

Mixtures

CaseReferenceSimulatorDeviationSource
Benzene-toluene bubble point, x = 0.5 at 1 atm
Flash an equimolar liquid to a vapour fraction of 0.001.
92.20 °CRaoult’s law with Antoine constants; measured 92.1
Benzene-toluene first vapour, y₁ at x = 0.5
Benzene fraction of the vapour outlet of the same flash.
0.710 Raoult’s law with Antoine constants
Ethanol-water azeotrope temperature at 1 atm (NRTL)
Bubble point of x_ethanol = 0.894 with the NRTL package the flowsheet uses for this pair.
78.15 °CPerry’s Chemical Engineers’ Handbook
Ethanol-water azeotrope: vapour equals liquid
y_ethanol at the same point; at an azeotrope it equals x.
0.894 Perry’s Chemical Engineers’ Handbook

Units

CaseReferenceSimulatorDeviationSource
Heat of reaction, C₂H₄ + H₂ → C₂H₆
Conversion reactor; the heat of reaction is built from ideal-gas formation enthalpies.
-136.30 kJ/molNIST WebBook ΔfH° (C₂H₄ +52.5, C₂H₆ −83.8)
Pipe friction drop: water, 100 mm, 2770 kg/h, 100 m, ε = 0.046 mm
Darcy-Weisbach with the Churchill friction factor at Re ≈ 11 000.
148.5 PaColebrook equation iterated by hand, IAPWS water properties
Pipe friction factor for the same line
Churchill against Colebrook at the same Reynolds number.
0.0309 Colebrook equation
Pump head for a 2.93 bar rise on water
Head = ΔP / (ρ g) with the stream density.
29.96 mΔP / (ρ g), ρ = 997.2 kg/m³
Hydraulic power, 36 m³/h of water at 2.93 bar
Q·ΔP at 100 % efficiency.
2.930 kWQ·ΔP = 0.01 m³/s × 293 kPa

Rigorous column vs Aspen Plus

CaseReferenceSimulatorDeviationSource
Depropanizer: propane in the distillate
21-stage MESH column, feed on stage 10, R = 2.223, D = 40 kmol/h at 15 bar; Aspen Plus RadFrac with the same property method and specs.
0.98301 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: propane in the bottoms
Same column, bottoms composition.
0.01133 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: condenser duty
Total condenser, saturated liquid reflux and distillate.
477.37 kWAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: reboiler duty
Kettle reboiler.
646.71 kWAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: condenser temperature
Stage 1 (bubble point of the distillate).
44.48 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: reboiler temperature
Stage 21.
109.71 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer: feed-stage temperature (stage 10)
From the stage profile; Aspen gives 345.261 K.
72.11 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer, partial condenser and Murphree 0.7: propane in the vapour distillate
Same column with a partial (vapour) condenser and a vapour Murphree efficiency of 0.7 on stages 2-20.
0.96292 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer, partial condenser and Murphree 0.7: condenser duty
Partial condenser duty.
338.33 kWAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer, partial condenser and Murphree 0.7: top temperature
Dew point of the vapour distillate.
47.16 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Depropanizer with a 10 kmol/h liquid side draw on stage 15: propane in the side product
Aspen PRODUCTS SIDE 15 L MOLE-FLOW=10; the draw leaves at the stage liquid composition.
0.10735 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Side draw temperature (stage 15)
Same column.
95.80 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Side-draw column: reboiler duty
Same column.
649.67 kWAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Side draw plus a 30 kmol/h pumparound (stage 8 → 4, −30 kW): reboiler duty
Aspen PUMPAROUND P-1 8 4 DRAW-PHASE=L TYPE=PARTIAL DUTY=−30 kW; with R and D fixed the removed heat lands on the reboiler.
680.04 kWAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Side draw plus pumparound: propane in the distillate
Same column.
0.96587 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Lean-oil absorber: lean gas leaving the top
8 adiabatic stages, 50 kmol/h n-decane on stage 1, 100 kmol/h gas (85/10/5 C1/C3/C4) on stage 8, 20 bar; no condenser or reboiler.
80.988 kmol/hAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Lean-oil absorber: n-butane left in the lean gas
Mole fraction in the gas leaving the top (the C4 recovery is 99.98 %).
0.000014 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Lean-oil absorber: propane in the rich oil
Mole fraction in the liquid leaving the bottom.
0.12433 Aspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)
Lean-oil absorber: rich oil temperature
Heat of absorption warms the oil from 30 °C.
43.68 °CAspen Plus V14 RadFrac, PENG-ROB, same specifications (run 2026-11-09)

The checks run in your browser against the public API each time this page is opened, so they reflect the deployed build, not a saved table. The Aspen Plus cases are written up with the full tables on the comparison page. Unit-balance and recycle-convergence tests run on every build in CI; see the theory page for what each unit computes.