Flowsheet Simulator

Validation

Process Tools vs Aspen Plus RadFrac

The rigorous column in the flowsheet simulator solves the same MESH equations a commercial simulator does: component balances, equilibrium relations and energy balances on every stage, solved simultaneously by Newton's method with K-values and enthalpies from a Peng-Robinson package. To see how close a free browser simulator gets, four cases were built in Aspen Plus V14 with identical specifications and run on 2026-11-09. The tables below are the Aspen block and stream reports next to the Process Tools results; the Process Tools column is re-computed live on the validation page every time it is opened.

1. Depropanizer, total condenser

Feed 40/40/20 propane / n-butane / n-pentane, 100 kmol/h at 50 °C and 15 bar. 21 equilibrium stages, feed on stage 10, total condenser, kettle reboiler, reflux ratio 2.223, distillate 40 kmol/h, 15 bar. Peng-Robinson in both.

QuantityAspen Plus V14Process ToolsDifference
Propane in distillate (mole fraction)0.983010.98288−0.00013
n-Butane in distillate0.0169710.01712+0.00015
Propane in bottoms0.0113260.01141+0.00009
Condenser duty477.37 kW477.67 kW+0.06 %
Reboiler duty646.71 kW647.01 kW+0.05 %
Boil-up ratio2.37092.371+0.0001
Condenser temperature44.48 °C44.54 °C+0.06 K
Feed-stage temperature (stage 10)72.11 °C72.12 °C+0.01 K
Reboiler temperature109.71 °C109.67 °C−0.04 K
Largest stage-temperature difference (21 stages)——0.1 K

2. Same column, partial condenser and Murphree efficiency 0.7

Vapour distillate (partial condenser) and a vapour Murphree efficiency of 0.7 on stages 2-20; everything else as above. Aspen: CONDENSER=PARTIAL-V, EFF=MURPHREE section 2-20.

QuantityAspen Plus V14Process ToolsDifference
Propane in vapour distillate0.962920.96272−0.00020
n-Butane in vapour distillate0.0368730.03708+0.00021
Propane in bottoms0.0247170.02486+0.00014
Condenser duty338.33 kW338.49 kW+0.05 %
Reboiler duty654.32 kW654.57 kW+0.04 %
Top temperature47.16 °C47.22 °C+0.06 K
Bottom temperature108.52 °C108.47 °C−0.05 K

3. Lean-oil absorber

100 kmol/h of gas (85 % methane, 10 % propane, 5 % n-butane) at 30 °C enters stage 8 of an 8-stage tower at 20 bar; 50 kmol/h of n-decane at 30 °C enters stage 1. No condenser, no reboiler, adiabatic stages. Aspen: CONDENSER=NONE, REBOILER=NONE.

QuantityAspen Plus V14Process ToolsDifference
Lean gas leaving the top80.988 kmol/h81.003 kmol/h+0.02 %
Rich oil leaving the bottom69.012 kmol/h68.997 kmol/h−0.02 %
Propane in lean gas0.0175280.01753+0.00000
n-Butane in lean gas0.00001390.00001390
Propane in rich oil0.124330.12436+0.00003
n-Butane in rich oil0.0724350.07245+0.00002
Lean gas temperature33.38 °C33.37 °C−0.01 K
Rich oil temperature43.68 °C43.67 °C−0.01 K
Largest stage-temperature difference (8 stages)——0.03 K

4. Depropanizer with a side draw and a pumparound

The first column plus a 10 kmol/h liquid side draw from stage 15 (bottoms 50 kmol/h); then also a 30 kmol/h liquid pumparound from stage 8 returned to stage 4 after removing 30 kW. Aspen: PRODUCTS SIDE 15 L, PUMPAROUND P-1 8 4 TYPE=PARTIAL DUTY=−30 kW.

QuantityAspen Plus V14Process ToolsDifference
Side draw: propane in the side product0.107350.10783+0.00048
Side draw: side product temperature95.80 °C95.75 °C−0.05 K
Side draw: reboiler duty649.67 kW649.91 kW+0.04 %
Side draw: propane in distillate0.967430.96726−0.00017
+ pumparound: reboiler duty680.04 kW680.28 kW+0.04 %
+ pumparound: condenser duty482.25 kW482.48 kW+0.05 %
+ pumparound: propane in distillate0.965870.96571−0.00016
+ pumparound: propane in side product0.113320.11379+0.00047
+ pumparound: bottom temperature111.68 °C111.64 °C−0.04 K
+ pumparound: boil-up ratio2.98912.9915+0.0024

Both simulators show the same thing about the pumparound: with the reflux ratio and distillate rate fixed, the 30 kW it removes is supplied again by the reboiler (649.7 → 680.0 kW in Aspen, 649.9 → 680.3 kW here). A pumparound saves utility only when a purity specification is allowed to lower the reflux.

What is the same, what is not

  • Same equations. Equilibrium stages, MESH balances, Newton solution (Naphtali-Sandholm here, inside-out in RadFrac by default), Peng-Robinson K-values and enthalpies, vapour Murphree efficiencies defined the same way.
  • Same specifications. Stages, feed stage, reflux ratio, distillate rate, pressure, condenser and reboiler type map one to one; the shortcut column's Convert to rigorous column button does what DSTWU → RadFrac does.
  • Not covered here. Multiple feeds on a distillation column, thermosyphon reboilers, three-phase stages, rate-based mass transfer, tray hydraulics beyond Fair-correlation sizing, dynamics, electrolytes, solids. Aspen Plus has all of these; Process Tools is a screening tool.
  • Different databanks. Binary interaction parameters and liquid-density correlations differ, which is where the last digits go.

Try the same cases

Aspen Plus is a product of Aspen Technology, Inc. Process Tools is not affiliated with or endorsed by AspenTech; the comparison was made with a licensed copy for validation only.