Validation
Process Tools vs Aspen Plus RadFrac
The rigorous column in the flowsheet simulator solves the same MESH equations a commercial simulator does: component balances, equilibrium relations and energy balances on every stage, solved simultaneously by Newton's method with K-values and enthalpies from a Peng-Robinson package. To see how close a free browser simulator gets, four cases were built in Aspen Plus V14 with identical specifications and run on 2026-11-09. The tables below are the Aspen block and stream reports next to the Process Tools results; the Process Tools column is re-computed live on the validation page every time it is opened.
1. Depropanizer, total condenser
Feed 40/40/20 propane / n-butane / n-pentane, 100 kmol/h at 50 °C and 15 bar. 21 equilibrium stages, feed on stage 10, total condenser, kettle reboiler, reflux ratio 2.223, distillate 40 kmol/h, 15 bar. Peng-Robinson in both.
| Quantity | Aspen Plus V14 | Process Tools | Difference |
|---|---|---|---|
| Propane in distillate (mole fraction) | 0.98301 | 0.98288 | −0.00013 |
| n-Butane in distillate | 0.016971 | 0.01712 | +0.00015 |
| Propane in bottoms | 0.011326 | 0.01141 | +0.00009 |
| Condenser duty | 477.37 kW | 477.67 kW | +0.06 % |
| Reboiler duty | 646.71 kW | 647.01 kW | +0.05 % |
| Boil-up ratio | 2.3709 | 2.371 | +0.0001 |
| Condenser temperature | 44.48 °C | 44.54 °C | +0.06 K |
| Feed-stage temperature (stage 10) | 72.11 °C | 72.12 °C | +0.01 K |
| Reboiler temperature | 109.71 °C | 109.67 °C | −0.04 K |
| Largest stage-temperature difference (21 stages) | — | — | 0.1 K |
2. Same column, partial condenser and Murphree efficiency 0.7
Vapour distillate (partial condenser) and a vapour Murphree efficiency of 0.7 on stages 2-20; everything else as above. Aspen: CONDENSER=PARTIAL-V, EFF=MURPHREE section 2-20.
| Quantity | Aspen Plus V14 | Process Tools | Difference |
|---|---|---|---|
| Propane in vapour distillate | 0.96292 | 0.96272 | −0.00020 |
| n-Butane in vapour distillate | 0.036873 | 0.03708 | +0.00021 |
| Propane in bottoms | 0.024717 | 0.02486 | +0.00014 |
| Condenser duty | 338.33 kW | 338.49 kW | +0.05 % |
| Reboiler duty | 654.32 kW | 654.57 kW | +0.04 % |
| Top temperature | 47.16 °C | 47.22 °C | +0.06 K |
| Bottom temperature | 108.52 °C | 108.47 °C | −0.05 K |
3. Lean-oil absorber
100 kmol/h of gas (85 % methane, 10 % propane, 5 % n-butane) at 30 °C enters stage 8 of an 8-stage tower at 20 bar; 50 kmol/h of n-decane at 30 °C enters stage 1. No condenser, no reboiler, adiabatic stages. Aspen: CONDENSER=NONE, REBOILER=NONE.
| Quantity | Aspen Plus V14 | Process Tools | Difference |
|---|---|---|---|
| Lean gas leaving the top | 80.988 kmol/h | 81.003 kmol/h | +0.02 % |
| Rich oil leaving the bottom | 69.012 kmol/h | 68.997 kmol/h | −0.02 % |
| Propane in lean gas | 0.017528 | 0.01753 | +0.00000 |
| n-Butane in lean gas | 0.0000139 | 0.0000139 | 0 |
| Propane in rich oil | 0.12433 | 0.12436 | +0.00003 |
| n-Butane in rich oil | 0.072435 | 0.07245 | +0.00002 |
| Lean gas temperature | 33.38 °C | 33.37 °C | −0.01 K |
| Rich oil temperature | 43.68 °C | 43.67 °C | −0.01 K |
| Largest stage-temperature difference (8 stages) | — | — | 0.03 K |
4. Depropanizer with a side draw and a pumparound
The first column plus a 10 kmol/h liquid side draw from stage 15 (bottoms 50 kmol/h); then also a 30 kmol/h liquid pumparound from stage 8 returned to stage 4 after removing 30 kW. Aspen: PRODUCTS SIDE 15 L, PUMPAROUND P-1 8 4 TYPE=PARTIAL DUTY=−30 kW.
| Quantity | Aspen Plus V14 | Process Tools | Difference |
|---|---|---|---|
| Side draw: propane in the side product | 0.10735 | 0.10783 | +0.00048 |
| Side draw: side product temperature | 95.80 °C | 95.75 °C | −0.05 K |
| Side draw: reboiler duty | 649.67 kW | 649.91 kW | +0.04 % |
| Side draw: propane in distillate | 0.96743 | 0.96726 | −0.00017 |
| + pumparound: reboiler duty | 680.04 kW | 680.28 kW | +0.04 % |
| + pumparound: condenser duty | 482.25 kW | 482.48 kW | +0.05 % |
| + pumparound: propane in distillate | 0.96587 | 0.96571 | −0.00016 |
| + pumparound: propane in side product | 0.11332 | 0.11379 | +0.00047 |
| + pumparound: bottom temperature | 111.68 °C | 111.64 °C | −0.04 K |
| + pumparound: boil-up ratio | 2.9891 | 2.9915 | +0.0024 |
Both simulators show the same thing about the pumparound: with the reflux ratio and distillate rate fixed, the 30 kW it removes is supplied again by the reboiler (649.7 → 680.0 kW in Aspen, 649.9 → 680.3 kW here). A pumparound saves utility only when a purity specification is allowed to lower the reflux.
What is the same, what is not
- Same equations. Equilibrium stages, MESH balances, Newton solution (Naphtali-Sandholm here, inside-out in RadFrac by default), Peng-Robinson K-values and enthalpies, vapour Murphree efficiencies defined the same way.
- Same specifications. Stages, feed stage, reflux ratio, distillate rate, pressure, condenser and reboiler type map one to one; the shortcut column's Convert to rigorous column button does what DSTWU → RadFrac does.
- Not covered here. Multiple feeds on a distillation column, thermosyphon reboilers, three-phase stages, rate-based mass transfer, tray hydraulics beyond Fair-correlation sizing, dynamics, electrolytes, solids. Aspen Plus has all of these; Process Tools is a screening tool.
- Different databanks. Binary interaction parameters and liquid-density correlations differ, which is where the last digits go.
Try the same cases
- Rigorous depropanizer — the first table, with stage profiles.
- Lean-oil absorber — the third table.
- Validation page — all 35 checks, including these, recomputed live against reference equations of state and NIST data.
Aspen Plus is a product of Aspen Technology, Inc. Process Tools is not affiliated with or endorsed by AspenTech; the comparison was made with a licensed copy for validation only.