Flowsheet Simulator

Flowsheet example

Two-Stage Compression Train with Intercooling

Methane / ethane gas: 1 → 4 → 16 bar with a cooler between stages; compare the power with and without intercooling.

A 90/10 methane / ethane gas at 30 °C and 1 bar (500 kmol/h) is compressed to 4 bar, cooled back to 40 °C and compressed to 16 bar. Each stage is modelled with an isentropic efficiency of 0.75: the ideal outlet comes from a PS flash and the real enthalpy rise is the ideal rise divided by the efficiency.

The intercooler is what makes two stages cheaper than one: compare the total shaft power with a single 1 → 16 bar compressor by deleting the cooler and the second stage, or sweep the first-stage discharge pressure to find the split that minimises power (close to the geometric mean, 4 bar).

The compressor inspector hands off to the compressor sizing calculator with the gas, flow and pressures filled in, and the Economics panel prices the shaft power as electricity.

What to look at

  • About 830 kW total shaft power; the first-stage outlet is well above 150 °C.
  • Intercooler duty is the enthalpy the cooling water has to carry between the stages.
  • Sweep COMP1 outlet pressure from 2 to 8 bar and plot both powers.

The sheet

Components: methane, ethane · property package: PR · 5 units, 4 streams.

UnitTypeParameters
FEED1FeedTemperature: 30 °C · Pressure: 1 bar · Basis: Molar (kmol/h, mole fractions) · Molar flow: 500 kmol/h · Mole fractions: methane: 0.90, ethane: 0.10
COMP1CompressorSpecification: Outlet pressure · Outlet pressure: 4 bar · Isentropic efficiency: 0.75
COOL1CoolerSpecification: Outlet temperature · Outlet temperature: 40 °C · Pressure drop: 0.1 bar
COMP2CompressorSpecification: Outlet pressure · Outlet pressure: 16 bar · Isentropic efficiency: 0.75
PROD1Product—

Streams: S1 (FEED1 → COMP1), S2 (COMP1 → COOL1), S3 (COOL1 → COMP2), S4 (COMP2 → PROD1).

Other examples

  • LPG transfer line with a booster pump — Liquid propane / n-butane through 300 m of 80 mm line rising 12 m, a pump, then 500 m of 100 mm line: Darcy-Weisbach drops, adiabatic.
  • Flash with liquid recycle — Propane / n-butane: heat, flash, recycle 80 % of the liquid. One tear stream, Wegstein converges in a few passes.
  • Depropanizer (shortcut column) — Propane / n-butane / n-pentane feed, Fenske-Underwood-Gilliland column at 15 bar, 98 % propane overhead.
  • Depropanizer (rigorous column) — The same feed through a 21-stage MESH column at the reflux and distillate rate the shortcut found: stage profiles, exact duties.
  • Lean-oil absorber (rigorous) — n-Decane oil absorbs propane and butane from a methane-rich gas in 8 equilibrium stages at 20 bar: no condenser, no reboiler, heat of absorption in the profile.
  • Ethylene hydrogenation reactor — C2H4 + H2 → C2H6 in a methane-diluted feed: an adiabatic reactor (watch the temperature rise), then a cooler.
  • Ethylene hydrogenation PFR (kinetic) — The hydrogenation feed through a 2 m³ plug-flow reactor with second-order Arrhenius kinetics (illustrative constants): conversion and temperature profiles.
  • Feed-effluent heat exchanger — Ethanol / water: a hot stream heats a cold one in a counter-current exchanger; LMTD, UA and the minimum approach are reported.