Flowsheet example
Depropanizer Simulation: Shortcut Column (FUG)
Propane / n-butane / n-pentane feed, Fenske-Underwood-Gilliland column at 15 bar, 98 % propane overhead.
A 40/40/20 propane, n-butane, n-pentane feed at 50 °C and 16 bar (100 kmol/h) is let down through a valve to 15 bar and sent to a shortcut column that recovers 98 % of the propane overhead while letting 2 % of the n-butane escape with it.
Relative volatilities are taken from the Peng-Robinson K-values at the top and bottom of the feed’s flash envelope; Fenske gives the minimum stages and the distribution of n-pentane, Underwood the minimum reflux, Gilliland the stages at 1.3 times the minimum reflux and Kirkbride the feed stage. Products are saturated liquids; the condenser duty is the enthalpy change of the top vapour and the reboiler closes the energy balance.
From the column’s inspector the sheet hands off to McCabe-Thiele (as a propane / n-butane pseudo-binary), to a relief valve on the overhead vapour and to the pressure-vessel calculator for the shell, and the Economics panel sizes the shell by the Souders-Brown diameter and prices the steam and cooling water.
What to look at
- About 21 theoretical stages at R ≈ 2.2 with the feed near the middle.
- Condenser about 480 kW of cooling water, reboiler about 650 kW of steam: the Economics panel turns both into $/yr.
- Sweep the light-key recovery from 0.90 to 0.995 and watch the stage count climb.
The sheet
Components: propane, n-butane, n-pentane · property package: PR · 5 units, 4 streams.
| Unit | Type | Parameters |
|---|---|---|
| FEED1 | Feed | Temperature: 50 °C · Pressure: 16 bar · Basis: Molar (kmol/h, mole fractions) · Molar flow: 100 kmol/h · Mole fractions: propane: 0.40, n-butane: 0.40, n-pentane: 0.20 |
| VLV1 | Valve | Specification: Outlet pressure · Outlet pressure: 15 bar |
| COL1 | Distillation (shortcut) | Column pressure (blank = feed): 15 bar · Light key: propane · Heavy key: n-butane · Light key to distillate: 0.98 · Heavy key to distillate: 0.02 · R / Rmin: 1.3 |
| Distillate | Product | — |
| Bottoms | Product | — |
Streams: S1 (FEED1 → VLV1), S2 (VLV1 → COL1), S3 (COL1 → Distillate), S4 (COL1 → Bottoms).
Other examples
- LPG transfer line with a booster pump — Liquid propane / n-butane through 300 m of 80 mm line rising 12 m, a pump, then 500 m of 100 mm line: Darcy-Weisbach drops, adiabatic.
- Flash with liquid recycle — Propane / n-butane: heat, flash, recycle 80 % of the liquid. One tear stream, Wegstein converges in a few passes.
- Depropanizer (rigorous column) — The same feed through a 21-stage MESH column at the reflux and distillate rate the shortcut found: stage profiles, exact duties.
- Lean-oil absorber (rigorous) — n-Decane oil absorbs propane and butane from a methane-rich gas in 8 equilibrium stages at 20 bar: no condenser, no reboiler, heat of absorption in the profile.
- Two-stage compression with intercooling — Methane / ethane gas: 1 → 4 → 16 bar with a cooler between stages; compare the power with and without intercooling.
- Ethylene hydrogenation reactor — C2H4 + H2 → C2H6 in a methane-diluted feed: an adiabatic reactor (watch the temperature rise), then a cooler.
- Ethylene hydrogenation PFR (kinetic) — The hydrogenation feed through a 2 m³ plug-flow reactor with second-order Arrhenius kinetics (illustrative constants): conversion and temperature profiles.
- Feed-effluent heat exchanger — Ethanol / water: a hot stream heats a cold one in a counter-current exchanger; LMTD, UA and the minimum approach are reported.