Flowsheet Simulator

Flowsheet example

LPG Pipeline Simulation with a Booster Pump

Liquid propane / n-butane through 300 m of 80 mm line rising 12 m, a pump, then 500 m of 100 mm line: Darcy-Weisbach drops, adiabatic.

A 60/40 propane and n-butane liquid at 20 °C and 12 bar leaves storage at 150 kmol/h, climbs 12 m through 300 m of 80 mm suction line with six fittings, is boosted 8 bar by a pump at 70 % efficiency, runs 500 m of 100 mm discharge line and fills a day tank sized for 24 h.

Each pipe segment computes its Darcy-Weisbach drop with the Churchill friction factor at the inlet state: density and viscosity come from the Peng-Robinson package, not from a table. The outlet is an isenthalpic flash, so if the pressure fell below the bubble point the vapour fraction would show it.

The pump adds its hydraulic work as enthalpy, which is why the outlet is a fraction of a degree warmer, and the Economics panel costs the pump by shaft power and the tank by volume.

What to look at

  • Suction line: the 12 m rise accounts for most of the 0.78 bar drop; friction at 0.73 m/s is small.
  • Pump outlet: about 19.9 bar and a small temperature rise, the irreversibility of a 70 % efficient pump.
  • Sweep the suction diameter down to 50 mm and watch the line pressure approach the bubble point.

The sheet

Components: propane, n-butane · property package: PR · 6 units, 5 streams.

UnitTypeParameters
FEED1FeedTemperature: 20 °C · Pressure: 12 bar · Basis: Molar (kmol/h, mole fractions) · Molar flow: 150 kmol/h · Mole fractions: propane: 0.60, n-butane: 0.40
Suction linePipe segmentLength: 300 m · Inner diameter: 80 mm · Roughness: 0.046 mm · Elevation rise: 12 m · Fittings ΣK: 6
PUMP1PumpSpecification: Pressure rise · Pressure rise: 8 bar · Efficiency: 0.7
Discharge linePipe segmentLength: 500 m · Inner diameter: 100 mm · Roughness: 0.046 mm · Elevation rise: 0 m · Fittings ΣK: 10
Day tankStorage tankResidence time: 24 h · Fill fraction: 0.85
To plantProduct—

Streams: S1 (FEED1 → Suction line), S2 (Suction line → PUMP1), S3 (PUMP1 → Discharge line), S4 (Discharge line → Day tank), S5 (Day tank → To plant).

Other examples

  • Flash with liquid recycle — Propane / n-butane: heat, flash, recycle 80 % of the liquid. One tear stream, Wegstein converges in a few passes.
  • Depropanizer (shortcut column) — Propane / n-butane / n-pentane feed, Fenske-Underwood-Gilliland column at 15 bar, 98 % propane overhead.
  • Depropanizer (rigorous column) — The same feed through a 21-stage MESH column at the reflux and distillate rate the shortcut found: stage profiles, exact duties.
  • Lean-oil absorber (rigorous) — n-Decane oil absorbs propane and butane from a methane-rich gas in 8 equilibrium stages at 20 bar: no condenser, no reboiler, heat of absorption in the profile.
  • Two-stage compression with intercooling — Methane / ethane gas: 1 → 4 → 16 bar with a cooler between stages; compare the power with and without intercooling.
  • Ethylene hydrogenation reactor — C2H4 + H2 → C2H6 in a methane-diluted feed: an adiabatic reactor (watch the temperature rise), then a cooler.
  • Ethylene hydrogenation PFR (kinetic) — The hydrogenation feed through a 2 m³ plug-flow reactor with second-order Arrhenius kinetics (illustrative constants): conversion and temperature profiles.
  • Feed-effluent heat exchanger — Ethanol / water: a hot stream heats a cold one in a counter-current exchanger; LMTD, UA and the minimum approach are reported.